446 research outputs found

    Punkaharjun toimintayksikön vuosikertomus 2006

    Get PDF

    Impact of Mesh and Fixation on Chronic Inguinal Pain in Lichtenstein Hernia Repair : 5-Year Outcomes from the Finn Mesh Study

    Get PDF
    Objective To find out the mesh fixation technique that minimises chronic pain in Lichtenstein hernioplasty. Summary background data Mesh fixation may affect chronic pain and recurrence after inguinal hernia surgery, but long-term results of comparative trials are lacking. Methods Lichtenstein hernioplasty was performed under local anaesthesia on 625 patients in day care units. The patients were randomised to receive either a cyanoacrylate glue (n = 216), self-gripping mesh (n = 202) or non-absorbable 3-0 polypropylene sutures (n = 216) for the fixation of mesh. A standardised telephone interview or postal questionnaire was conducted 5 years after the index operation. The patients with complaints suggesting recurrence or chronic pain (visual analogue scale >= 3, 0-10) were examined clinically. The rate of occasional pain, chronic severe pain, recurrence, re-operations, daily use of analgesics, overall patient satisfaction and sensation of a foreign object were recorded. Results A total of 82% of patients (n = 514) completed the 5-year audit including 177, 167 and 170 patients in the glue, self-fixation and suture groups, respectively. There were no significant differences in the incidence of pain (7-8%), operated recurrences (2-4%), overall re-operations (4-5%), need for analgesics (1-2%), patient's satisfaction (93-97%) or in the feeling of a foreign object (11-18%) between the study groups. Conclusion The choice of the mesh or fixation method had no effect on the overall long-term outcome, pain or recurrence of hernia. Less penetrating fixation (glue or self-gripping mesh) is a safe option for the fixation of mesh in Lichtenstein hernia repair.Peer reviewe

    Slurry and dry particle erosion wear properties of WC-10Co4Cr and Cr3C2-25NiCr hardmetal coatings deposited by HVOF and HVAF spray processes

    Get PDF
    Thermally sprayed hardmetal coatings were produced to provide improved erosion wear compared to conventional cast GX4CrNi13-4 martensitic steel (CA6NM) used in hydro turbine components. Sprayed coatings and reference materials were tested with high-speed slurry pot tester using either fine or coarse quartz as the erosive media. Additional erosion tests were carried out with centrifugal dry erosion tester. Tungsten carbide based coatings provided the highest wear resistance due to the high hardness and even distribution of the fine carbide particles. The cast 13-4 steel samples experienced up to 180 times higher wear rates in fine quartz slurry and up to 36 times higher wear rates in coarse slurry compared to the sprayed coatings

    A missense substitution A49T in the steroid 5-alpha-reductase gene (SRD5A2) is not associated with prostate cancer in Finland

    Get PDF
    Prostatic steroid 5-alpha-reductase gene (SRD5A2) encodes a critical enzyme involved in the conversion of testosterone to dihydrotestosterone. A germline mis-sense substitution (A49T) leads to a variant SRD5A2 protein, which has a 5-fold higher in vitro V max than the wild-type protein (Ross et al, 1998; Makridakis et al, 1999). The A49T variant was recently associated with 2.5 to 3.28-fold increased risk of prostate cancer (PC) in African-American and Hispanic men (Makridakis et al, 1999). Also, Jaffe et al (2000) reported an association between A49T and more aggressive disease among Caucasian patients. Here, we report that the prevalence of the A49T variant in 449 Finnish PC patients was 6.0%, not significantly different from 6.3% observed in 223 patients with benign prostatic hyperplasia or 5.8% in 588 population-based controls (odds ratio for PC 1.04, 95% C.I. 0.62–1.76 P = 0.89). There was no association between A49T and the family history of the patients nor with tumour stage or grade. Our results argue against a prominent role of the A49T variant as a genetic risk factor for prostate cancer development and progression in the Finnish population. © 2001 Cancer Research Campaign www.bjcancer.co

    Factors predicting chronic pain after open inguinal hernia repair : a regression analysis of randomized trial comparing three different meshes with three fixation methods (FinnMesh Study)

    Get PDF
    Correction: Volume: 22 Issue: 5 Pages: 819-819 DOI: 10.1007/s10029-018-1788-y WOS:000446065400016Chronic pain after inguinal hernioplasty is the foremost side-effect up to 10-30% of patients. Mesh fixation may influence on the incidence of chronic pain after open anterior mesh repairs. Some 625 patients who underwent open anterior mesh repairs were randomized to receive one of the three meshes and fixations: cyanoacrylate glue with low-weight polypropylene mesh (n = 216), non-absorbable sutures with partially absorbable mesh (n = 207) or self-gripping polyesther mesh (n = 202). Factors related to chronic pain (visual analogue scores; VAS ae 30, range 0-100) at 1 year postoperatively were analyzed using logistic regression method. A second analysis using telephone interview and patient records was performed 2 years after the index surgery. At index operation, all patient characteristics were similar in the three study groups. After 1 year, chronic inguinal pain was found in 52 patients and after 2 years in only 16 patients with no difference between the study groups. During 2 years' follow-up, three (0.48%) patients with recurrences and five (0.8%) patients with chronic pain were re-operated. Multivariate regression analysis indicated that only new recurrent hernias and high pain scores at day 7 were predictive factors for longstanding groin pain (p = 0.001). Type of mesh or fixation, gender, pre-operative VAS, age, body mass index or duration of operation did not predict chronic pain. Only the presence of recurrent hernia and early severe pain after index operation seemed to predict longstanding inguinal pain.Peer reviewe

    Exploiting Sparse Representations for Robust Analysis of Noisy Complex Video Scenes

    Full text link
    Abstract. Recent works have shown that, even with simple low level visual cues, complex behaviors can be extracted automatically from crowded scenes, e.g. those depicting public spaces recorded from video surveillance cameras. However, low level features as optical flow or fore-ground pixels are inherently noisy. In this paper we propose a novel unsupervised learning approach for the analysis of complex scenes which is specifically tailored to cope directly with features ’ noise and uncer-tainty. We formalize the task of extracting activity patterns as a matrix factorization problem, considering as reconstruction function the robust Earth Mover’s Distance. A constraint of sparsity on the computed basis matrix is imposed, filtering out noise and leading to the identification of the most relevant elementary activities in a typical high level behavior. We further derive an alternate optimization approach to solve the pro-posed problem efficiently and we show that it is reduced to a sequence of linear programs. Finally, we propose to use short trajectory snippets to account for object motion information, in alternative to the noisy optical flow vectors used in previous works. Experimental results demonstrate that our method yields similar or superior performance to state-of-the arts approaches.

    Investigation of human apoB48 metabolism using a new, integrated non-steady-state model of apoB48 and apoB100 kinetics

    Get PDF
    Background Triglyceride-rich lipoproteins and their remnants have emerged as major risk factors for cardiovascular disease. New experimental approaches are required that permit simultaneous investigation of the dynamics of chylomicrons (CM) and apoB48 metabolism and of apoB100 in very low-density lipoproteins (VLDL). Methods Mass spectrometric techniques were used to determine the masses and tracer enrichments of apoB48 in the CM, VLDL1 and VLDL2 density intervals. An integrated non-steady-state multicompartmental model was constructed to describe the metabolism of apoB48- and apoB100-containing lipoproteins following a fat-rich meal, as well as during prolonged fasting. Results The kinetic model described the metabolism of apoB48 in CM, VLDL1 and VLDL2. It predicted a low level of basal apoB48 secretion and, during fat absorption, an increment in apoB48 release into not only CM but also directly into VLDL1 and VLDL2. ApoB48 particles with a long residence time were present in VLDL, and in subjects with high plasma triglycerides, these lipoproteins contributed to apoB48 measured during fasting conditions. Basal apoB48 secretion was about 50 mg day?1, and the increment during absorption was about 230 mg day?1. The fractional catabolic rates for apoB48 in VLDL1 and VLDL2 were substantially lower than for apoB48 in CM. Discussion This novel non-steady-state model integrates the metabolic properties of both apoB100 and apoB48 and the kinetics of triglyceride. The model is physiologically relevant and provides insight not only into apoB48 release in the basal and postabsorptive states but also into the contribution of the intestine to VLDL pool size and kinetics.Peer reviewe

    Primary aldosteronism : Higher volume load, cardiac output and arterial stiffness than in essential hypertension

    Get PDF
    Background The diagnostics of primary aldosteronism (PA) are usually carried out in patients taking antihypertensive medications. We compared haemodynamics between medicated PA, medicated essential hypertension (EH), never-medicated EH and normotensive controls (n = 130 in all groups). Methods The hypertensive groups were matched for age (53 years), sex (84 male/46 female) and body mass index (BMI) (30 kg m(-2)); normotensive controls had similar sex distribution (age 48 years, BMI 27 kg m(-2)). Haemodynamics were recorded using whole-body impedance cardiography and radial pulse wave analysis, and the results were adjusted as appropriate. Radial blood pressure recordings were calibrated by brachial blood pressure measurements from the contralateral arm. Results Radial and aortic systolic and diastolic blood pressure was similar in PA and never-medicated EH, and higher than in medicated EH and normotensive controls (PPeer reviewe
    • …
    corecore